General information
In een handig formaat dat in de palm van de hand past, combineert de MaxiLog Alert robuuste temperatuurmonitoring met eenvoudige gegevensuitwisseling via een ingebouwde USB-interface met directe download naar software. Verkrijgbaar voor standaard- en lage temperatuurmonitoring, zijn deze single- en multi-use loggers voorzien van opties om de starttijdvertraging, meetintervallen, hoge en lage alarmwaarden, alarmtype en meetgegevens aan te passen.
Modellen
SpotSee
8018-S MaxiLogAlert Single-Use 8018-MMaxiLog Alert Multi-Use |
SpotSee
8114-S MaxiLog Alert -80C Single-Use 8114-M MaxiLog Alert -80C Multi-Use |
SpotSee
7050-G2 MaxiLog |
|
Recording Type | Single-Use(may be overwritten prior to starting unit), Multi-Use | Single-Use(may be overwritten prior to starting unit), Multi-Use | Single Use |
Temperature Measurement Range | -29°C to +72°C /
-20°F to +162°F |
-80°C to +30°C /
-113°F to +86°F |
-30°C to +70°C /
-22°F to +158°F |
Temperature Accuracy Range | ±0.2°C at 0°C to 10°C,
±0.9°C at extremes / ±.36°F at 32°F to 50°F, ±1.8°F at extremes |
±0.5°C at 0°C to 10°C,
±2.0°C at extremes / ±0.9°F at 32°F to 50°F, ±3.6°F at extremes |
±0.3°C / 0.54°F |
Temperature Resolution | 0.1°C / 1.8°F | 0.1°C / 1.8°F | 0.1°C / 1.8°F |
Data Storage Capacity | 32K with up to 31,980 data points | 32K with up to 31,980 data points | 14K with up to 14,400 data points |
Battery Life / Type | CR2032 Lithium coin cell, 1 yr operating life,
2 yr shelf life |
ER2450T,
1 yr operating life, 2 yr shelf life |
CR2032 Lithium coin cell, 18 month shelf life |
Data Sampling Interval | 2 seconds to 36 hours | 2 seconds to 36 hours | 10 Minutes |
Start Up Delay | 2 seconds to 36 hours | 2 seconds to 36 hours | 30 Minutes |
Alarm Programming | Programmable high and low limits. Alarm triggered when limits are exceeded for specified time period. | Programmable high and low limits. Alarm triggered when limits are exceeded for specified time period. | Programmable highand low limits. Alarm trigged when limits exceeded. |
Alarm Modes | Exceed Limit,Continuous Interval, Cumulative | Exceed Limit,Continuous Interval, Cumulative | Exceed Limit |
Alarm Reset Options | Single Use: No reset option Multi-Use: Alarm is reset when loggeris erased and reprogrammed | Single Use: No reset option Multi-Use: Alarm is reset when loggeris erased and reprogrammed | Single Use: No reset option |
Alarm Notifications | Red LED flashes when alarm has been triggered | Red LED flashes when alarm has been triggered | Red LED flashes when alarm has been triggered |
Indicators | LED Indicators:on/recording (green), alarm (red flash) | LED Indicators:on/recording (green), alarm (red flash) | LED Indicators:on/recording (green), alarm (red flash) |
Start Up Options | Push buttonautomatic start with optional delay | Push buttonautomatic start with optional delay | Push button: Start/Mark/Stop |
Dimensions | 8.8 cm (l) x 3.49 cm (w) x
1.58 cm (h) / 3.5 in (l) x 1.38 in (w) x 0.62 in (h) |
8.8 cm (l) x 3.49 cm (w) x
1.58 cm (h) / 3.5 in (l) x 1.38 in (w) x 0.62 in (h) |
94mm (h) x 20 mm (w) x 7 mm (h) / 3.7 in (l) x
0.8 in (w) x 0.27 in (h) |
Weight | 65 g / 3.0 oz | 65 g / 3.0 oz | 10.6 g / 0.37 oz. |
Quality Assurance Certifications | CE, NIST Traceable, Certificate of Calibration | CE, NIST Traceable, Certificate of Calibration | CE, NIST Traceable, Certificate of Calibration |
Minimum System Requirements | Windows XP, Vista: 7, 8 and 10 | Windows XP, Vista: 7, 8 and 10 | Windows XP, Vista: 7, 8 and 10, MAC and Android |
Required Software | c\temp+ (read only) | MDAS-Pro, 21 CFR (user configurable) | c\temp+ (read only) | MDAS-Pro, 21 CFR (user configurable) | PDF Reader |
Computer Interface | USB A, built-in interface | USB A, built-in interface | USB A, built-in interface |
Warranty | 1 Year | 1 Year | 1 Year |